1. Remove the black cap from each syringe.
2. Twist the syringe to syringe adapter (red) onto the end of each syringe to connect the 2 syringes together.
3. Inject the contents of the liquid component into the powder syringe, and mix the syringes back and forth 30-40 times.
4. Leave the syringes connected and allow the product time to stiffen.
5. ***The material will be too thin to use for approximately 20 minutes.
6. Remix the syringes approximately 10 times.
7. Push all ofthe contents into 1of the syringes, and then unscrew the syringe from the adapter.
8. Attach the Flowthru™ Standard Style 20 gauge tip and place the material into the tooth.
1. Clinical signs and symptoms recorded
2. Preoperative radiograph taken
3. Achieve Anesthesia
4. Isolate tooth with rubber dam
5. Access opening performed and necrotic pulp tissue removed
6. Enlarge orifices of canal openings to create a medication cavity
7. Walls of pulp chamber chemically
8. Cleansed with 35% phosphoric acid for 1minute
9. If any hemorrhage present controlledby applying 10% NaOCL on cotton pellet
10. Seal with glass ionomer cement
11. Restore with stainless steel crown